The Riello CMG88 62D2 is the control box that starts, watches and safely stops a Riello 40 FS gas burner. So, if your burner locks out or won’t light, this box is one of the first parts to check. In this guide, we explain what it does, how to spot a fault and how a technician replaces it.

What is the Riello CMG88 62D2?
It is the brain of the burner. In short, it runs the start-up steps, reads the flame signal and cuts the gas if anything goes wrong. Riello fits it on the 40 FS5, FS10 and FS20 gas burners, and its part number is 3013073.
Not sure which box your burner needs? Then see our guide to which Riello control box fits your burner.
What does the Riello CMG88 62D2 do?
It handles four key jobs:
- Start-up: first, it runs the fan to purge the chamber, then sparks and opens the gas valve.
- Flame watch: after that, it reads the flame signal all the time.
- Safety lockout: if the flame fails, it shuts the gas off at once.
- Fault light: finally, it shows a lockout, so the technician knows to check and reset.
As a result, your oven or boiler stays safe, even when no one is watching it.
What are the signs of a faulty Riello CMG88 62D2?
First, rule out simple causes. For example, a dirty flame sensor, no gas or a worn electrode can look like a box fault. Then check for these signs:
- The burner locks out again and again, even after a reset.
- It does not start, although power is fine.
- Your fan runs, but ignition never happens.
- Also, the burner shuts down during work for no clear reason.
- Finally, the box has burn marks or smells burnt.
If you see several of these, the box may need replacing. Still, a trained technician should confirm it.
How does a technician replace the Riello CMG88 62D2?
Only a trained burner technician should do this work. Typically, they follow these steps:
- First, switch off the power and close the gas valve.
- Next, note the wiring before removing anything.
- Then unplug the old box from its base.
- After that, fit the new CMG88.62D2 in the same place.
- Finally, restore power and gas, and test a full start.

How can I make the control box last longer?
- Keep the burner and flame sensor clean.
- Also, check wiring and plugs at every service.
- Protect the burner panel from water, dust and heat.
- Then book a yearly check with a trained technician.
Where can I buy the Riello CMG88 62D2 in India?
You can buy the Riello CMG88 62D2 from our online shop. Or visit Riello industrial oil and gas burners in Vasai (E). In addition, we ship spares across India. Before you order, we also help you match the part to your burner.
For more on the burners that use this box, see the Riello 40 FS series page. Then WhatsApp us at +91 98197 08885 for the price.
Frequently asked questions
What is the Riello CMG88 62D2 used for?
It controls ignition, watches the flame and locks out the burner if a fault occurs. Mainly, Riello fits it on 40 FS gas burners.
How do I know if my control box is faulty?
Repeated lockouts, no spark or sudden shutdowns often point to it. However, check the flame sensor, electrode and gas supply first.
Can I replace the control box myself?
No. Gas burners carry real safety risks, so a trained technician should fit and test it.
Will it fit my Riello burner?
It fits most Riello 40 FS5, FS10 and FS20 burners. Still, send us your burner model so we can confirm.
Do you deliver across India?
Yes. We ship burner spares to buyers across India.
Contact us
Riello industrial oil and gas burners
Gala No. 204, B Block, Prime Trade Center, Waliv Phata, Sativali Road, Vasai (E) – 401208, Maharashtra