Combustion and Control Systems

← Back to articles

Siemens LFS1.11A2 Flame Safeguard: What It Does and When to Replace It

The Siemens LFS1.11A2 is a flame safeguard that watches the burner flame and signals the moment it fails. Learn how it works, where it is used and how to pick the right version.

The Siemens LFS1.11A2 is a flame safeguard: an electronic unit that watches the burner flame and reports straight away if the flame goes out. Paired with a flame detector, it lets the burner control shut off the fuel before unburnt oil or gas can build up. That makes it one of the most important safety parts on a boiler, furnace or heater.

Siemens LFS1.11A2 flame safeguard - Combustion & Control Systems Mumbai

What does a flame safeguard do?

A burner must never keep sending fuel into a furnace without a flame. The flame safeguard prevents this. It receives a signal from a flame detector and passes a clear “flame on” or “flame off” signal to the burner control system.

When the flame fails, its signal contacts switch over. As a result, the burner control closes the fuel valves and stops the burner safely.

How does the Siemens LFS1.11A2 work?

Siemens builds the LFS1 range as microprocessor-based units with a plug-in design. The LFS1.11 version is approved for continuous operation, supervising oil and gas flames with an RAR9 photocell detector. Its main features include:

  • A multicolour LED that shows the flame signal at a glance
  • A DC 0–10 V output that indicates flame signal strength
  • Potential-free signal contacts for the burner control system
  • Safety rating up to SIL3 in continuous operation with the RAR9 detector
  • Marine classification approvals, so it also suits marine boilers

LFS1.11A2 vs LFS1.11A1 vs LFS1.21: which do you need?

LFS1.11A2220–230 V version, for use with the RAR9 photocell
LFS1.11A1110–120 V version of the same unit
LFS1.21A1 / A2For an ionisation probe, or for QRA2, QRA4 and QRA10 UV flame detectors

In other words, the last digit tells you the supply voltage, while “11” or “21” tells you which flame detector it works with. So check both your control panel voltage and your detector type before ordering.

Where is this flame safeguard used?

You will find it on oil and gas burners in:

  • Steam and hot water boilers
  • Thermal fluid heaters
  • Furnaces and incinerators
  • Dryers and hot air generators
  • Marine boilers and combustion systems

It is used with burners from Baltur, Riello, Ecoflam, Weishaupt, Oilon, Bentone and other brands.

When should you replace it?

Consider a replacement if you see any of these:

  1. Frequent false flame failures, even though the flame looks steady and the detector is clean
  2. No flame signal on the LED while the burner is clearly firing
  3. Burnt terminals, moisture damage or a cracked housing
  4. A unit that has passed its design life in a safety-critical plant

However, check the flame detector first. A dirty or faulty photocell often causes the same symptoms. We also stock the Siemens QRB4B flame detector and other Siemens burner controls such as the LMO24.111C2 oil burner controller.

See it on Instagram

We shared photos of this unit, including the 110 V and 220 V versions, on Instagram. View the Siemens LFS1.11A2 post on Instagram.

Buy Siemens LFS1.11A2 in Mumbai

Riello industrial oil and gas burners supplies Siemens burner controls and spare parts from Gala No. 204, B Block, Prime Trade Center, Waliv Phata, Sativali Road, Vasai (E) – 401208. We deliver across Mumbai, Thane, Navi Mumbai, Bhiwandi, Vasai-Virar and the rest of India.

View the Siemens LFS1.11A2 product page or WhatsApp us for the price.

Frequently asked questions

Is the LFS1.11A2 a complete burner controller?
No. It supervises the flame and gives a flame signal. The burner control or PLC handles the start-up sequence and the fuel valves.

Which flame detector works with it?
The LFS1.11 version works with the Siemens RAR9 photocell detector.

What is the difference between A1 and A2?
A1 is the 110–120 V version and A2 is the 220–230 V version.

Can it be used on marine boilers?
Yes. The LFS1 range carries marine classification approvals.

How do I get the price?
Send a photo of your old unit’s label on WhatsApp at +91 98197 08885.