The Riello FS10 gas burner (model Riello 40 FS10) is a compact, single-stage (on/off) forced-draught burner rated at 42 to 116 kW, which is about 36,000 to 1,00,000 kcal/hr. It suits small boilers, hot water generators, bakery ovens, dryers and process heaters running on natural gas (PNG) or, in its LPG version, on LPG. So, if your heat load falls in this band and you want a simple burner with easy-to-find spare parts, it is one of the most practical choices.

Riello FS10 gas burner single stage 42-116 kW

Key takeaways

  • Output: 42 – 116 kW (about 36,000 – 1,00,000 kcal/hr), single stage.
  • Fuel: natural gas as standard; LPG with the dedicated FSP10 version.
  • Best for small boilers, ovens, dryers and air heaters.
  • Supplied in India with Brahma, Dungs or Elektrogas gas valves.
  • Below about 55 kW, consider the FS5; above about 110 kW, the FS20.

What is the Riello 40 FS10 and how does it work?

The FS10 is the middle model of Riello’s 40 FS series. It sits between the smaller FS5 and the larger FS20. Because all three share the same basic design, a technician who knows one model can usually service the others.

The working cycle is simple:

  1. First, the thermostat or pressure switch on your boiler or oven calls for heat.
  2. Then the control box starts the fan and pre-purges the combustion chamber with air.
  3. Next, the air pressure switch confirms that the fan is delivering air.
  4. After that, the gas valve opens and the ignition electrode sparks to light the flame.
  5. Finally, an ionisation probe confirms the flame. If no flame is detected, the control box shuts the gas and goes into lockout.

Since it is a single-stage burner, it fires at one set rate. In other words, it is either fully on or off. As a result, the design stays simple, which is why it is so popular for small and medium loads.

Riello FS10 gas burner specifications at a glance

The figures below come from Riello’s 40 FS series technical data. Even so, always confirm the details for your unit from its rating plate and manual.

ParameterValue
Thermal output42 – 116 kW (36,000 – 1,00,000 kcal/hr)
OperationSingle stage (on/off)
FuelNatural gas; LPG with the FSP10 version
Natural gas flow4.2 – 11.6 Nm³/h
LPG flow (FSP10)1.6 – 4.4 Nm³/h
Minimum gas pressure (natural gas)18 mbar
Electrical supplySingle phase, 230 V, 50 Hz
Flame detectionIonisation probe
StandardApproved to EN 676

FS5 vs FS10 vs FS20: which Riello model fits?

ModelOutputTypical use
40 FS523 – 58 kWSmall ovens, fryers, small dryers
40 FS1042 – 116 kWSmall boilers, rotary ovens, powder coating ovens
40 FS2081 – 220 kWLarger boilers, dryers and air heaters

In short, the FS10 fills the gap for mid-size loads. For more detail on the smaller model, also read our Riello 40 FS5 guide.

Where is this burner used in Indian industries?

In Mumbai and across India, the Riello FS10 gas burner is commonly used for:

  • Small boilers and hot water generators in hotels, hospitals, laundries and food units.
  • Bakery and rotary rack ovens, where a clean gas flame matters for product quality.
  • Powder coating and paint drying ovens in small fabrication units.
  • Dryers and air heaters for textiles, spices, pharma and packaging lines.
  • Replacing old diesel burners when a plant shifts to PNG or LPG.

Is the FS10 the right size for my boiler or oven?

Sizing is the most common mistake buyers make. For example, a burner that is too large cycles on and off too often. On the other hand, one that is too small never reaches temperature.

Therefore, use this simple check:

  1. First, find the heat input your boiler or oven needs. It is usually on the rating plate or in the manual.
  2. If you only know the useful output, divide it by the efficiency. For instance, an 81 kW boiler at 90% efficiency needs about 90 kW of burner input.
  3. Also remember that 1 kW is about 860 kcal/hr, in case your equipment is rated in kcal/hr.
  4. Finally, check that the required input falls comfortably inside 42 – 116 kW, not right at the edge.

In addition, check the combustion chamber size, the draught and the flame length. If your load is below about 55 kW, the FS5 may suit you better. However, above about 110 kW, you should look at the FS20 instead of the Riello FS10 gas burner.

Gas valve options: Brahma, Dungs or Elektrogas?

In India, this burner is supplied with different gas valve arrangements. A common choice is the FS10 and FS20 with Brahma EG12 SR GMO valve. Meanwhile, versions with a Dungs multibloc or an Elektrogas valve are also available.

  • Brahma EG12 – a compact, widely used valve with easy availability of replacements. You can learn more in our Brahma EG12 SR GMO valve guide.
  • Dungs multibloc – combines filter, regulator and safety valves in one body.
  • Elektrogas – another proven option used on many European burners.

Whichever valve you choose, make sure the gas train also has a filter, a pressure regulator and a pressure gauge. Above all, it must suit your gas type and supply pressure.

Which Riello FS10 parts need attention over time?

Like any burner, it has a few parts that wear or need cleaning. That is why keeping one or two of them in stock can save days of downtime.

  • Control box – Riello gas burner control boxes such as the CMG88.62D2. Always match the code on your old unit.
  • Ionisation probe and lead – a dirty or loose probe often causes lockout. See the probe connection for FS5, FS10 and FS20.
  • Ignition electrode – check the gap and clean any carbon build-up.
  • Fan wheel and air intake – dust reduces air flow and therefore spoils combustion.
  • Gas valve coil and filter – check them during yearly servicing.

What should I check before buying?

Before you order a Riello FS10 gas burner, run through this short checklist:

  • Fuel type: natural gas (PNG) or LPG, since the setup differs.
  • Required heat input in kW or kcal/hr, worked out as above.
  • Gas supply pressure at the burner point.
  • Preferred gas valve make: Brahma, Dungs or Elektrogas.
  • Blast tube length and mounting flange to suit your boiler or oven.
  • A genuine Riello rating plate and serial number, so that you avoid duplicates.
  • Spare parts and service support near your plant.

Finally, have the burner commissioned by a trained technician with a flue gas analyser. After all, a correct air-gas setting improves both fuel efficiency and safety.

Buy the Riello 40 FS10 gas burner in Mumbai

You can buy this burner from Riello industrial oil and gas burners (Combustion & Control Systems), Gala No. 204, B Block, Prime Trade Center, Waliv Phata, Sativali Road, Vasai (E) – 401208, Maharashtra. We have worked with burners and combustion systems since 1996. In addition, we supply the FS5 and FS20, gas valves, control boxes and spare parts. You can also view the FS5, FS10 and FS20 range with Brahma gas valve.

We supply customers in Mumbai, Thane, Navi Mumbai, Bhiwandi, Vasai-Virar and across India. Message us on WhatsApp for the delivery time to your location.

Simply share your boiler or oven details, fuel type and gas pressure with us, and we will help you confirm the right model.

Get a price on WhatsApp

Frequently asked questions

What is the output of this burner?
Riello rates it at 42 to 116 kW, which is about 36,000 to 1,00,000 kcal/hr.

Can the FS10 run on LPG?
Yes, but only in its LPG version, which Riello lists as the FSP10. Therefore, do not simply connect an LPG line to a natural gas burner.

Is it a two-stage or modulating burner?
No. It is a single-stage, on/off burner. So, for two-stage or modulating control, you need a different Riello series.

Why does my FS10 go into lockout?
Common causes include a dirty ionisation probe, a wrong electrode gap, low gas pressure, a faulty air pressure switch or a failing control box. For this reason, a technician should find the cause before resetting it again and again.

What is the difference between the FS10 and the FS20?
Both share the same design. However, the FS20 covers a higher output of 81 to 220 kW, so choose based on the heat input your equipment needs.