Siemens RAR9 Photocell Flame Detector for Oil Burners – Genuine Siemens
Genuine Siemens RAR9 photocell (photoresistive flame detector) for yellow-flame oil burners. Ready stock in Mumbai with fast delivery. WhatsApp +91 98197 08885 for price.
Product description

Siemens RAR9 Photocell for Oil Burner Flame Detection
The Siemens RAR9 is a photoresistive flame detector (photocell) that watches the yellow flame of an oil burner. It sends the flame signal to the burner controller, which shuts the burner down if the flame is lost. Combustion & Control Systems, Mumbai keeps the Siemens RAR9 in ready stock.
RAR9 Technical Specifications
| Model | RAR9 |
| Brand | Siemens |
| Type | Photoresistive flame detector (photocell) |
| Degree of protection | IP20 |
| Ambient temperature | -20 °C to +60 °C |
| Humidity | Below 95 % RH |
| Weight | Approx. 85 g |
Key Features
- Reliable detection of yellow oil flames
- Works with Siemens oil burner controls such as the LAL series
- Simple plug-in replacement
- Small size for easy mounting on the burner
Applications
- Oil burners on boilers, thermic fluid heaters and ovens
- Burners from Ecoflam, Oilon, Weishaupt, Riello, Baltur, Bentone and FBR fitted with RAR detectors
Why Buy the Siemens RAR9 photocell flame detector from Us
- Genuine, new and original parts only – no refurbished stock
- Ready stock in Mumbai for fast dispatch across India and export to the Middle East and Africa
- Supplying burners and burner spares since 1997
- Technical help with model selection, wiring and replacement
- GST invoice and safe, tracked packing
Related products: Siemens LAL 3.25 Oil Burner Controller, Siemens QRA2 UV Flame Detector. Manufacturer information: Siemens.
Frequently Asked Questions
Which controller works with the Siemens RAR9?
It is commonly used with Siemens LAL oil burner controls. Check your controller datasheet or send us a photo of the wiring.
Why does my burner lock out with a Siemens RAR9?
A dirty or weak photocell, wrong alignment or a faulty controller can cause lockouts. Clean the lens first, then replace if the signal stays low.
Can the Siemens RAR9 be used on gas burners?
No. Gas flames are blue and need a UV detector or ionisation probe.
Need the Siemens RAR9 photocell flame detector urgently? Send the model number or a photo of the label on WhatsApp +91 98197 08885 and we will confirm price and stock the same day.
Request a quotation